Install Instruction:
Specification:
① Power:Input: AC220V Output: DC12V
② Power consumptionin static:≤1.5W(a.c)
③ Ambient temperature:1~55℃; Moisture: ≤95%
④ Suitable water pressure:0.05MPa - 0.6MPa
⑤ Detection zone:Default Setting is 5-8M.
⑥ Dia.of inlet/outlet pipe:(DN15)G1/2″
⑦ Dimensions:107*58*64mm
⑧Standard: CJ/T194-2004
Features & Functions:
Flush Automatically: When people come into its detection zone, it will flush automatically.
Clean & Hygienic: Self-open and close without any touch can effectively avoid cross-
infection of bacteria.
Water-saving: It only flushes when someone comes to use, saving water very dramatically.
Intelligent: Its control circuit is super mini-designed. The detection zone has been configured before Ex-factory.
Any manual adjustment is needless.
|